Table 37: Moisture cell installation: point of insertion

*Ground level taken as the upper surface of the former shop floor (14.30m AOD)

Cell numberSite identification (Logger 'L' & Cell 'C')Parameter monitored by cellExposed face within inspection chamberApproximate cell position, metres from ground level*Depth of insertion into deposit (mm)
1L1/C1Resistance & temperatureNorth facing1.1250
2L1/C2Resistance & temperatureNorth facing1.7885
3L1/C4ResistanceWest facing1.2585
4L1/C3Resistance & temperatureWest facing1.8185
5L2/C5Resistance & temperatureEast facing0.95100
6L2/C8ResistanceEast facing1.10100
7L2/C7Resistance & temperatureEast facing1.35114
8L2/C6Resistance & temperatureEast facing1.68100
9L3/C9Resistance & temperatureSouth facing0.9960
10L3/C11ResistanceSouth facing1.22115
11L3/C12ResistanceSouth facing1.46110
12L3/C13ResistanceSouth facing1.64110
13L3/C10Resistance & temperatureSouth facing1.80112

 PREVIOUS   NEXT   CONTENTS   HOME 

© Author(s). Content published prior to 2013 is not covered by CC-BY licence and requests for reproduction should usually go to the copyright holder (in most cases, the author(s)). For citation / fair-dealing purposes, please attribute the author(s), the title of the work, the Internet Archaeology journal and the relevant URL/DOI.